AcuitSign M8 Patient Monitoring System 50/60Hz Frequency 1280×1024 Pixels Resolution

SHENZHEN CHANGKE CONNECT ELECTRONICS CO.,LTD.

AcuitSign M8 Patient Monitoring System 50/60Hz Frequency 1280×1024 Pixels Resolution

Brand Name : SINOHERO

Model Number : AcuitSign M8

Certification : CE, ISO

Place of Origin : CHINA

Payment Terms : T/T, L/C, D/P, Western Union

Delivery Time : 7-15 working days

Power Voltage : AC 100-240V 50/60Hz

Standard module slot : 4

Resolution : 1280×1024 pixels

Paper length : 15m

alarm Level : Low, medium and high

Weight : ≦11kg

Contact Now

Technical Specifications of AcuitSign M8

 

 

Size and Weight

  • Size:434mm×389mm×206mm
  • Weight:≦11kg
  • Standard module slot:4
  • Additional module rack Slot:1

 

Power supply

  • Power Voltage: AC 100-240V 50/60Hz
  • Power Input: ≦150VA
  • Input Current:1.7~0.8V
  • Safety class: Category I

 

Display

  • 17〞 Color Anti-glare TFT-LCD
  • Resolution:1280×1024 pixels

 

Battery

  • Type: Rechargeable Lithium battery,11.1V/4.0AH
  • Operating time under the normal use and full charge:≧60minutes

(2 batteries for 120 minutes)

 

Recorder

  • Method: Thermal dot array
  • Paper width:50mm(1.97 in)
  • Paper length:15m
  • Paper Speed:12.5/25/50(mm/sec)
  • Traces: Maximum 3 tracks
  • Recording way: Real-time recording, Periodic recording, Alarm recording

 

Alarm

  • Level: Low, medium and high
  • Indication: Auditory and visual
  • Patient Physiological Alarm Light color: Yellow & Red:
  • Equipment Technical Alarm Light color: Blue
  • Supports Pitch Tone and multi-level volume;
  • Supports custom arrhythmia tone

 

Input device

  • Touch button: standard config, support operation of shortcut menu.
  • knob: standard config
  • Mouse input: Support
  • Keyboard input: Support

 

System Output & Extensible Interfaces

  • Ethernet Network:2 Standard RJ45 socket
  • Defibrillation Output:1 RJ11 socket
  • Nurse Call:1 BNC socket
  • Video Output:1 DVI port,1VGA port
  • USB1.1 port:6
  • Auxiliary Module Rack connector.1
  • SD memory card:2G (standard config)
  • Analog Output(ECG or IBP):Option

 

Trend & Reviewing

  • Trend:168 hours
  • NIBP measurement reviewing:1000 groups
  • ARR event:128 groups of ARR event and the associated waveform
  • Alarm events:128 groups of parameter alarm events and associated parameter
  • Waveform at the alarm moment

Holographic waveform: The storage time depends on the stored waveforms and

The quantity of them.

 

Environment

  • Operating temperature:0~+40℃
  • Storage temperature:-20℃ to +50℃
  • Operating humisity:15%to85%(non condensing)
  • Storage humidity :10% to 93%(non condensing)
  • Operating atmospheric pressure:860hPa to 1060hPa
  • Storage atmospheric pressure:500hPa to 1060hPa

 

Safety:

  • IEC60601-1 Approved, CE marking according to MDD93/42/EEC

 

ECG

  • Lead Mode:3-leads ECG input

5-leads ECG input

12-leads ECG input

  • Lead selection:Ⅰ,Ⅱ,Ⅲ

Ⅰ,Ⅱ,Ⅲ,aVR,aVL,aVF,V-

Ⅰ,Ⅱ,Ⅲ, aVR,aVL,aVF,V1~V6(option)

  • Gain: 2.5mm/mV(×0.25), 5mm/mV(×0.5), 10mm/mV(×1),

20mm/mV(×2), 40mm/mV(×4),Auto

  • CMRR: Monitor mode≧105dB

Surgery mode≦105dB

Diagnostic mode≧90dB

  • Frequency response(-3d B):

Monitor mode 0.5~40Hz

Surgery mode 1~25Hz

Diagnostic mode 0.05~150Hz

  • input impedance: ≧5.0Mohm
  • ECG signal range:±10.0mV
  • Electrode offset potential: ±500mV
  • Patient Leakage Current:<10uA
  • Standardizing signal:1mV±5%
  • Baseline recovery:<5s after Defibrillation.(Mon or Surg mode)
  • Indication of electrode separation: Every electrode(exclusive of RL)
  • Protection: Breakdown Voltage 4000AVC 50/60Hz;defibrillator proof
  • Sweep speed:12.5mm/s,25mm/s,50mm/s

 

HR

  • Range: Adult 10~300bpm

Pediatric & Neonate:10~350bpm

  • Refreshing time:≦50 bpm Per2 pulses

50~120bpm per 4 pulses

≧120bpm per 6 pulses

  • Resolution: 1bpm
  • Accuracy: ±1% or ±1bpm,whichever is greater

 

ST segment

  • Measurement range:-2.0mV~2.0mV
  • Accuracy:-0.8mV~0.8mV: ±0.02mV or ±10% whichever is greater

Over ±0.8mV:unspecified

  • Resolution:0.01mV

 

RESP

  • Method: Thoracic impedance
  • Lead Selected from:Ⅰ(RA-LA)orⅡ(RA-LL);Default:Ⅰ
  • Gain: ×0.25, ×1, ×2, ×4
  • Bandwidth:0.25Hz to 2.0Hz (-3dB)
  • Sweep Speed: 6.25mm/s,12.5mm/s,25mm/s
  • Measurement Range:0~150 rpm
  • Resolution: 1rpm
  • Accuracy: ±2rpm or 2% whichever is greater
  • Delay of Apnea Alarm:10s,15s,25s,30s,35s,40s,45s,50s,55s,60s

 

NIBP

  • Way of measurement: Automatic oscillometry
  • Range of measurement:

Adult: SYS 30~270mmHg

DIA 10~220mmHg

MAP 20~235mmHg

Child: SYS 30~235mmHg

DIA 10~220mmHg

MAP 20~225mmHg

 

Neonate:SYS 30~135mmHg

DIA 10~100mmHg

MAP 20~125mmHg

  • Cuff pressure range:0~300mmHg
  • Resolution:1mmHg
  • Pressure Accuracy: Static:±2% or ±3mmHg,whichecer is greater

Clinical: ±5mmHg average error

Standard deviation:≦8mmHg

  • Unit: mmHg, kPa
  • Measurement mode: Manual, Auto, STAT
  • Intervals for AUTO measurement time:1,2,3,4,5,10,15,30,60,90 minutes;

2,4,8,12hours

  • STAT mode cycle time: keep 5 minutes, at 5 seconds interval.
  • Overpressure Protection: Hardware and software double protections
  • Pulse rate range:40~240bpm

 

Standard SpO2(Digital)

  • Measurement Range:0~100%
  • Resolution:1%
  • Accuracy: At70~100%,±2%

At0~69%,unspecified

PR

  • Measurement Range:25~255bpm
  • Resolution:1bpm
  • Accuracy: ±1% or ±1bpm,whichever is greater

 

Nellcor-SpO2

  • Measurement Range:0~100%
  • Resolution:1%
  • Accuracy:At70~100%:±2%(Adult)

At70~100%:±3%(Neonate)

At70~100%:±2%(Low Perfusion)

At0~69%,unspecified

PR

  • Measurement Range:20~300bpm
  • Resolution:1bpm
  • Accuracy: 20bpm to 250bpm: ±3bpm

251bpm to 300bpm: unspecified

 

Masimo-SpO2

  • Measurement Range:0% to 100%
  • Resolution:1%
  • Accuracy: 70% to 100%:±2%(adult/pediatric,non-motion conditions)

70% to 100%:±3%(neonate,non-motion conditions)

70% to 100%:±3%(motion conditions)

0% to 69%, unspecified

  • Average time:2-4s,4-6s,8s,10s,12s,14s,16s

 

PR

  • Measurement Range:25bpm to 24bpm
  • Accuracy: ±3bpm(non-motion conditions)

±5bpm(motion conditions)

  • Resolution:1bpm

 

TEMP

  • Max Channel:8
  • Measurement way: Thermal resistance way
  • Measurement Range: 0.0℃~50.0℃(32℉~122℉)
  • Accuracy: ±0.1℃ or ±1℉(exclusive of probe)
  • Resolution: 0.1℃ or 1℉
  • Unit: Celsius(℃),Fahrenheit(℉)
  • Connecting cable: Compatible with YSI-400 serial

 

IBP

  • Max Channel: 8
  • Measurement way: Directly invasive pressure measurement
  • Sensitivity of transducer: 5uV/V/mmHg, ±2%
  • Impedance of transducer: 300 to 3000Ω
  • Measurement Range: -50~+350mmHg
  • Resolution: 1mmHg
  • Unit: mmHg, kpa, cmH2O
  • Accuracy:

Static: ±1mmHg or ±2%, whichever is grater(exclusive of transducer)

±4mmHg or ±4%, whichever is grater(inclusion of transducer)

Dynamic: ±4mmHg or 4%, whichever is grater

Transducer sites: Arterial Pressure (ART)

Pulmonary Artery Pressure (PA)

Left Atrium Pressure (LAP)

Right Atrium Pressure (RAP)

Central Venous Pressure (CVP)

Intracranial Pressure (ICP)

P1/P2

 

  • Selection of measurement range:

ART:0~+350mmHg

PA:-10~+120mmHg

CVP/RAP/LAP/ICP:-10~+40mmHg

P1/P2:-50~+350mmHg

 

EtCO2(Sidestream)

  • Measure method: Infrared spectrum
  • Measure Range: 0.0~13.1%(0~99.6mmHg)
  • Resolution: 1mmHg
  • Unit: %,mmHg,kpa
  • Accuracy: 0% to 4.9%,±0.3%(±2.0mmHg)

5.0%to 13.1%,<±10%of the reading

  • Measurement range of awRR:3~150rpm
  • Calibration: Offset calibration:auto,manual,Gain calibration

 

EtCO2(Mainstream)

  • Measure method: Infrared spectrum
  • Warm up time: Capnogram displayed in less than 15 seconds,At an ambient

Temperature of 25℃,full specifications within 2 minutes.

  • Measure Range: 0.0~19.7%(0~150mmHg)
  • Resolution: 1mmHg
  • Rise time(10l/min):≦60ms
  • Unit: %,mmHg,kpa
  • CO2 Accuracy:0-40mmHg, ±2mmHg

41-70mmHg, ±5% of reading

71-100mmHg, ±8% of reading

101-150mmHg, ±10% of reading

(at 760 mmHg,ambient temperature of 35℃)

  • awRR measurement range:0~150rpm
  • awRR measurement Accuracy: ±1rpm

 

EtCO2(Microstream)

  • Measure method: Infrared spectrum
  • Warm up time: Capnogram displayed in less than 20 seconds, At an ambient

Temperature of 25℃,full specifications within 2 minutes.

  • Measure Range: 0.0-19.7%(0-150mmHg)
  • Resolution: 1mmHg
  • Unit: %,mmHg,kpa
  • CO2 Accuracy: 0-40mmHg, ±2mmHg

41-70mmHg, ±5% of reading

71-100mmHg, ±8% of reading

101-150mmHg, ±10% of reading

(At 760 mmHg,ambient temperature of 25℃)

(When RR>80 rpm, all the rang is ±12% of reading)

CO2 response time: <3S

  • awRR measurement range:2~150rpm
  • awRR measurement Accuracy: ±1rpm
  • Sample Flow Rate:50ml/min ±10ml/min

 

Multi Gas

  • Measure method: Infrared spectrum
  • Fi and ET values: CO2 ,N2O ,O2 ,AG(HAL,ISO,NEF,SEV,DES)
  • Resolution:1%
  • Unit:%
  • Calibration: Room air calibration automatically when changing airway

Adapter (<5 sec)

  • Warm-up time:<10S,full accuracy within 1min
  • Measurement and alarm range of AG
  • Gas Range Accuracy

CO2 0-10% ±(0.3% ABS+4%REL)

N2O 0-100% ±(2% ABS+8%REL)

O2 10-100% ±(2% ABS+2%REL)

HAL,ISO,ENF 0-5% ±(0.15% ABS+10%REL)

SEV 0-8% ±(0.15% ABS+10%REL)

DES 0-18% ±(0.15% ABS+10%REL)

  • awRR measurement range: 0~150rpm
  • awRR measurement Accuracy: ±1rpm
  • Rise time(flowing speed 10I/min)CO2≦90ms

O2≦300ms

N2O≦300ms

Hal,Iso,Enf,Sev,Des≦300ms

  • Total system response time :<1seconds

 

Noninvasive Cardio Output (ICG):

Method: Measurement of thoracic electrical bioimpedanc

  • Measurement Range:HR:40~250bpm

SV:5~250ml

SI:5~125ml/m2

C.O.:1.4~15L/mm

TFC:15~143KΩ

  • Accuracy: HR±2bpm

SV: unspecified

C.O unspecified

  • Alarm range: C.L.:0.0L/min/m2 to 15.0 L/min/m2 continuously adjustable

TFC: 10/KΩ to 150/kΩ continuously adjustable.

 

Standard Configuration of AcuitSign M8:

Mainunt:17″Anti-glare TFT-LCD display,4 Standard module slot,1Additional module rack Slot(for EMS all-in-one module),13 Touch buttons,2RJ45 internet socket,1 Defibrillation Output,1 Nurse Call socket,1 DVI port,1VGA port,6 USB1.1 port,1 Auxiliary Module Rack connector,2G SD memory card.

 

Option of AcuitSign M8:

EMS module:8 Kinds of option

Option Module: Sidesteam CO2 module, Microstream CO2 module, Mainstream CO2 module, AG module, ICG module, IBP module, Temp module, Nellcor SpO2 module, Masimo SpO2 module

Module Rack: Auxiliary Module Rack

Navigating: USB compatible mouse and keyboard.

Printing: 3 Channel Thermal Recorder

Mounting: Rolling stand, Wall mount

Battery:11.1V/4.0AH Rechargeable Lithium Battery (max 2 pcs),

Other options: External Display, Wireless Lan, Extensive Memory card, Analog Output (ECG or IBP), Full Touch Screen


Product Tags:

patient care monitoring system

      

hospital patient monitoring equipment

      
Buy cheap AcuitSign M8 Patient Monitoring System 50/60Hz Frequency 1280×1024 Pixels Resolution product

AcuitSign M8 Patient Monitoring System 50/60Hz Frequency 1280×1024 Pixels Resolution Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: SHENZHEN CHANGKE CONNECT ELECTRONICS CO.,LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)